﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Tabriz University of Medical Sciences</PublisherName>
      <JournalTitle>BioImpacts</JournalTitle>
      <Issn>2228-5652</Issn>
      <Volume>5</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2015</Year>
        <Month>08</Month>
        <DAY>14</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>Comparison of non-electrophoresis grade with electrophoresis grade BIS in NIPAM polymer gel preparation</ArticleTitle>
    <FirstPage>129</FirstPage>
    <LastPage>133</LastPage>
    <ELocationID EIdType="doi">10.15171/bi.2015.16</ELocationID>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Roghaye</FirstName>
        <LastName>Khodadadi</LastName>
      </Author>
      <Author>
        <FirstName>Azim</FirstName>
        <LastName>Khajeali</LastName>
      </Author>
      <Author>
        <FirstName>Alireza</FirstName>
        <LastName>Farajollahi</LastName>
      </Author>
      <Author>
        <FirstName>Parisa</FirstName>
        <LastName>Hajalioghli</LastName>
      </Author>
      <Author>
        <FirstName>Noorallah</FirstName>
        <LastName>Raeisi</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">10.15171/bi.2015.16</ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>03</Month>
        <Day>26</Day>
      </PubDate>
    </History>
    <Abstract>Introduction: The main objective of this study was to investigate the possibility of replacing electrophoresis cross-linker with non-electrophoresis N, N′-methylenebisacrylamide (BIS) in N-isopropyl acrylamide (NIPAM) polymer gel and its possible effect on dose response. Methods: NIPAM polymer gel was prepared from non-electrophoresis grade BIS and the relaxation rate (R2) was measured by MR imaging after exposing the gel to gamma radiation from Co-60 source. To compare the response of this gel with the one that contains electrophoresis grade BIS, two sets of NIPAM gel were prepared using electrophoresis and non-electrophoresis BIS and irradiated to different gamma doses. Results: It was found that the dose–response of NIPAM gel made from the non-electrophoresis grade BIS is coincident with that of electrophoresis grade BIS. Conclusion: Taken all, it can be concluded that the non-electrophoresis grade BIS not only is a suitable alternative for the electrophoresis grade BIS but also reduces the cost of gel due to its lower price.</Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Polymer gel dosimetry</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">NIPAM gel</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Cross linker agent</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">N</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value"> N′-Methylenebisacrylamide (BIS)</Param>
      </Object>
    </ObjectList>
  </Article>