Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction

Sanaz Sajedi-Amin 1, Karim Assadpour-Zeynali 1, Vahid Panahi-Azar 2, Abbas Kebriaeezadeh 3, Maryam Khoubnasabjafari 4, Khlalil Ansarin 4, Vahid Jouyban-Gharamaleki 5,6, Abolghasem Jouyban 6,7*

1 Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
2 Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
3 Department of Pharmacoeconomics and Pharmaceutical Administration, Faculty of Pharmacy, Pharmacoeconomics and Pharmaceutical Administration Research Center, Tehran University of Medical Sciences, Tehran, Iran
4 Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
5 Department of Mechatronic Engineering, International Campus, University of Tabriz, Tabriz, Iran
6 Kimia Idea Pardaz Azarbayjan (KIPA) Science Based Company, Tabriz University of Medical Sciences, Tabriz, Iran
7 Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
*Corresponding Author: Email: ajouyban@hotmail.com

Abstract

Introduction: Microextraction processes with UV-Vis measurement have been developed and validated for analysis of bosentan in biological samples.
Methods:
In this work, liquid–liquid microextraction procedures (DLLME & USAEME) were employed for cleanup, pre-concentration, and determination of bosentan in biological samples by UV-Vis spectroscopy at 270 nm. The method was validated and applied to the determination of bosentan in spiked serum, exhaled breath condensate and urine samples.
Results:
Various experimental factors including type of extraction and dispersive solvents and their volumes, pH, sonication time and centrifuging time were investigated. Under the optimum conditions, the method was linear in the range of 1.0–5.0 μg.mL−1, with coefficient of determination (R2) of > 0.998. The limit of detection (LOD) was 0.07 mg.L−1. Recovery of the target analyte in biological samples was 106.2%. The method could be easily applied for higher concentration of bosentan and needs more improvement for application in the pharmacokinetic investigations where more sensitive methods are required.
Conclusion:
A simple, low cost, precise and accurate spectrophotometric analysis of bosentan in biological samples after liquid-liquid microextraction were developed and validated for routine analyses.
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 2368

Your browser does not support the canvas element.


PDF Download: 1126

Your browser does not support the canvas element.

Submitted: 11 Aug 2015
Revision: 02 Dec 2015
Accepted: 19 Dec 2015
ePublished: 27 Dec 2015
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)